Bỏ qua để tới nội dung chính

Sunny Boy Control Hiển Thị Tin Nhắn Cảnh Báo: “Energy”

Energy” error message

Sunny Boy Control detected a deviation in the feed-in yield of an inverter. The message is output when an inverter has fed in less than the set percentage value of the average energy yield of all comparable devices. Among other factors, this may be attributable to differing conditions at the module field of a PV plant, e.g. partially covered by snow.

As such, for the winter months we recommend reducing the configurable percentage value, thereby increasing the tolerance for the average value. At 0%, for example, no error message is displayed at all.

You can set the tolerance value in the Sunny Boy Control menu under: “Settings > System > Tolerances > Energy”.

The installer password has to be entered before the value can be readjusted.

Bài viết được Solar SM biên dịch từ tài liệu kỹ thuật của SMA Solar Technology AG. Nếu sự cố chưa được giải quyết, hãy gửi yêu cầu hỗ trợ kỹ thuật hoặc gọi hotline 082 747 7272.